We are a leading Distributor / Channel Partner of barksdale uns1000-bn18 level switch, 4 ports multiple limit switches and euchner heavy duty safety switch from Noida, India.

Barksdale UNS1000-BN18 Level Switch

Request Callback

₹ 180000 / Piece Get Latest Price

Operating Temperature14 degree F to 194 degree F (-10 degree C to +90 degree C)
BrandBarksdale
Model NoUNS1000-BN18
ConstructionBrass
Float stopperBronze
FloatFoamed NBR (BUNA)
System of protectionIP65
Male thread3/4" NPTM 1" NPTM G1/2 M20 x 1.5
Electrical connectionM12 x 1,4-pin DIN EN 175301-803-A (former DIN 43650),4-pin Cable gland,w/ PVC cable
Electrical values0.7A,42 VAC; 0.2A,230 VAC Max 24 VDC; max 1 amp; max 15 VA/VV
Operating pressureMax. 4 bar (400 kPa = 58 psi)

Specifications:
Specific Gravity: Min. 0.64Depth of immersion of Float at Density 1: 0.59 ±0.08 inch (15 ±2 mm)Temperature switch:
Temperature range:

Indexing tolerance:
Differential gap:
Contact:Bimetal
10 K-steps
140 °F to 176 °F (+60 °C to +80 °C)
±5 K
30 ±15 K
NC (Normally Closed and opens at temp)
or
NO (Normally Open and closes at temp)Switching point: 1 float for 1 switching pointApprovals:cURus* See Product Configurator for additional options.

4 Ports Multiple Limit Switches

Request Callback

₹ 25000 / Piece Get Latest Price

Product Brochure
No. of Ports4 Ports
Switch TypeRotary Limit Switch
Rated Voltage240 VAC
Model Name/Number4590-567
Operating Frequency50 Hz
Ambient Operating Temperature125 Deg C
  • Small switch for installations where there is little space
  • Upright housing
  • Up to six switch stations
  • Special version for high temperature optional

EUCHNER Heavy Duty Safety Switch

Request Callback

₹ 45000 / Piece Get Latest Price

BrandEUCHNER
Model Name/NumberMGB
Housing MaterialReinforced plastic; die-cast zinc nickel-plated, stainless stee
Ip RatingIP65
INSTALATION OPERATIONDoor hinge DIN left
  • 1. release
  • 2 . Connection via cable entry, M20 x 1.5 or plug connector
  • 3 .Plug connector connection, either HC26, M23 (RC18) or M12, 12-pin
  • 4 .Operation of guard locking via IMP as control input on PLC (only 3 mA)
  • 5 .Monitoring outputs
    • 1.OD = ON when door is closed.
    • 2 .OT = Bolt tongue inserted in the evaluation module (in case of guard locking devices ready for operation of the solenoid. In case of interlocking devices corresponds to safety outputs)
    • 3 .OL = Guard locking solenoid locked in position (in case of guard locking devices: corresponds to safety outputs)
    • 4 .OI = Diagnostics, there is a fault